Downloads
Catalogue
Product drawings
BalconyDrain
To download the BalconyDrain specification information, click here.
RainTrak®
To download the RainTrak® specification information, click here.
ProfiLine
To download the ProfiLine specification information, click here.
Grates
Access units and grates
Channels
Adjustable length channels
Adjustable corner
Description | Length (mm) |
Width (mm) |
Height (mm) |
Weight (kg) |
Galvanised Part No. |
Stainless Steel Part No. |
||||
---|---|---|---|---|---|---|---|---|---|---|
Adjustable corner | 300 | 300 | - | 1.5 | 38634 | 38643 |
End plates
Description | Length (mm) |
Width (mm) |
Height (mm) |
Weight (kg) |
Galvanised Part No. |
Stainless Steel Part No. |
---|---|---|---|---|---|---|
Shallow section | n/a | 130 | 55-77 | 0.1 | 36950 | 36951 |
Intermediate section | n/a | 130 | 75-105 | 0.1 | 36793 | 36841 |
Deep section | n/a | 130 | 105-165 | 0.2 | 36811 | 36859 |
Drainage duct
Installation files
Specification clause
BalconyDrain
Grate type | Channel width (nominal) mm |
Channel depth (nominal) mm |
Specification code | Specification clause |
---|---|---|---|---|
Affiner |
85
|
25
|
S85-25-A
|
The floor channel and grates are to be type S-85-25-A (85mm wide, 25mm deep channel with Affiner grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd. The channels overall length, outlet position and outlet diameters are specified on drawing number/s ______.All components used within the scope of the systems are shown on drawing number/s ______. All work should be carried out strictly in accordance with the manufacturer's instructions and the installation details set out on drawing number/s ____. |
103
|
25
|
S103-25-A
|
The floor channel and grates are to be type S-103-25-A (103mm wide, 25mm deep channel with Affiner grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd. The channels overall length, outlet position and outlet diameters are specified on drawing number/s ______.All components used within the scope of the systems are shown on drawing number/s ______. All work should be carried out strictly in accordance with the manufacturer's instructions and the installation details set out on drawing number/s ____. | |
103
|
40
|
S103-40-A
|
The floor channel and grates are to be type S-103-40-A (103mm wide, 40mm deep channel with Affiner grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd. The channels overall length, outlet position and outlet diameters are specified on drawing number/s ______.All components used within the scope of the systems are shown on drawing number/s ______. All work should be carried out strictly in accordance with the manufacturer's instructions and the installation details set out on drawing number/s ____. | |
5 Star |
103
|
40
|
S103-40-5S
|
The floor channel and grates are to be type S-103-40-5S (103mm wide, 40mm deep channel with 5 Star grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd. The channels overall length, outlet position and outlet diameters are specified on drawing number/s ______.All components used within the scope of the systems are shown on drawing number/s ______. All work should be carried out strictly in accordance with the manufacturer's instructions and the installation details set out on drawing number/s ____. |
Linéaire |
85
|
25
|
S85-25-L
|
The floor channel and grates are to be type S-85-25-L (85mm wide, 25mm deep channel with Linéaire grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd. The channels overall length, outlet position and outlet diameters are specified on drawing number/s ______.All components used within the scope of the systems are shown on drawing number/s ______. All work should be carried out strictly in accordance with the manufacturer's instructions and the installation details set out on drawing number/s ____. |
103
|
25
|
S103-25-L
|
The floor channel and grates are to be type S-103-25-L (103mm wide, 25mm deep channel with Linéaire grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd. The channels overall length, outlet position and outlet diameters are specified on drawing number/s ______.All components used within the scope of the systems are shown on drawing number/s ______. All work should be carried out strictly in accordance with the manufacturer's instructions and the installation details set out on drawing number/s ____. | |
103
|
40
|
S103-40-L
|
The floor channel and grates are to be type S-103-40-L (103mm wide, 40mm deep channel with Linéaire grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd. The channels overall length, outlet position and outlet diameters are specified on drawing number/s ______.All components used within the scope of the systems are shown on drawing number/s ______. All work should be carried out strictly in accordance with the manufacturer's instructions and the installation details set out on drawing number/s ____. | |
Tile |
85
|
25
|
S85-25-T
|
The floor channel and grates are to be type S-85-25-T (85mm wide, 25mm deep channel with Tile grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd. The channels overall length, outlet position and outlet diameters are specified on drawing number/s ______.All components used within the scope of the systems are shown on drawing number/s ______. All work should be carried out strictly in accordance with the manufacturer's instructions and the installation details set out on drawing number/s ____. |
103
|
25
|
S103-25-T
|
The floor channel and grates are to be type S-103-25-T (103mm wide, 25mm deep channel with Tile grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd. The channels overall length, outlet position and outlet diameters are specified on drawing number/s ______.All components used within the scope of the systems are shown on drawing number/s ______. All work should be carried out strictly in accordance with the manufacturer's instructions and the installation details set out on drawing number/s ____. | |
103
|
40
|
S103-40-T
|
The floor channel and grates are to be type S-103-40-T (103mm wide, 40mm deep channel with Tile grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd. The channels overall length, outlet position and outlet diameters are specified on drawing number/s ______.All components used within the scope of the systems are shown on drawing number/s ______. All work should be carried out strictly in accordance with the manufacturer's instructions and the installation details set out on drawing number/s ____. |
RainTrak®
Type | Grate type | Channel width (nominal) mm |
Specification code | Specification clause |
---|---|---|---|---|
RainTrak-O |
Linéaire
|
75
|
RTO75L
|
The floor channel and grates are to be type RTO75L (75mm wide, variable depth channel with Linéaire grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd.The channels overall depth, length, outlet position/s and outlet diameter/s are specified on drawing number/s __________.All components used within the scope of the systems are shown on drawing number/s __________. All work should be carried out strictly in accordance with the manufacturers instructions and the installation details set out on drawing number/s __________. |
100
|
RTO100L
|
The floor channel and grates are to be type RTO100L (100mm wide, variable depth channel with Linéaire grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd.The channels overall depth, length, outlet position/s and outlet diameter/s are specified on drawing number/s __________.All components used within the scope of the systems are shown on drawing number/s __________. All work should be carried out strictly in accordance with the manufacturers instructions and the installation details set out on drawing number/s __________. | ||
123
|
RTO123L
|
The floor channel and grates are to be type RTO123L (123mm wide, variable depth channel with Linéaire grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd.The channels overall depth, length, outlet position/s and outlet diameter/s are specified on drawing number/s __________.All components used within the scope of the systems are shown on drawing number/s __________. All work should be carried out strictly in accordance with the manufacturers instructions and the installation details set out on drawing number/s __________. | ||
Affiner
|
75
|
RTO75A
|
The floor channel and grates are to be type RTO75A (75mm wide, variable depth channel with Affiner grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd.The channels overall depth, length, outlet position/s and outlet diameter/s are specified on drawing number/s __________.All components used within the scope of the systems are shown on drawing number/s __________. All work should be carried out strictly in accordance with the manufacturers instructions and the installation details set out on drawing number/s __________. | |
100
|
RTO100A
|
The floor channel and grates are to be type RTO100A (100mm wide, variable depth channel with Affiner grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd.The channels overall depth, length, outlet position/s and outlet diameter/s are specified on drawing number/s __________.All components used within the scope of the systems are shown on drawing number/s __________. All work should be carried out strictly in accordance with the manufacturers instructions and the installation details set out on drawing number/s __________. | ||
123
|
RTO123A
|
The floor channel and grates are to be type RTO123A (123mm wide, variable depth channel with Affiner grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd.The channels overall depth, length, outlet position/s and outlet diameter/s are specified on drawing number/s __________.All components used within the scope of the systems are shown on drawing number/s __________. All work should be carried out strictly in accordance with the manufacturers instructions and the installation details set out on drawing number/s __________. | ||
RainTrak-E |
Linéaire
|
75
|
RTE75L
|
The floor channel and grates are to be type RTE75L (75mm wide, variable depth channel with Linéaire grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd. The channel will be supplied with an enclosed sill section, made to suit as per dimensions on drawing number __________. The channels overall depth, length, outlet position/s and outlet diameter/s are specified on drawing number/s __________.All components used within the scope of the systems are shown on drawing number/s __________. All work should be carried out strictly in accordance with the manufacturers instructions and the installation details set out on drawing number/s __________. |
100
|
RTE100L
|
The floor channel and grates are to be type RTE100L (100mm wide, variable depth channel with Linéaire grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd. The channel will be supplied with an enclosed sill section, made to suit as per dimensions on drawing number __________. The channels overall depth, length, outlet position/s and outlet diameter/s are specified on drawing number/s __________.All components used within the scope of the systems are shown on drawing number/s __________. All work should be carried out strictly in accordance with the manufacturers instructions and the installation details set out on drawing number/s __________. | ||
123
|
RTE123L
|
The floor channel and grates are to be type RTE123L (123mm wide, variable depth channel with Linéaire grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd. The channel will be supplied with an enclosed sill section, made to suit as per dimensions on drawing number __________. The channels overall depth, length, outlet position/s and outlet diameter/s are specified on drawing number/s __________.All components used within the scope of the systems are shown on drawing number/s __________. All work should be carried out strictly in accordance with the manufacturers instructions and the installation details set out on drawing number/s __________. | ||
Affiner
|
75
|
RTE75A
|
The floor channel and grates are to be type RTE75A (75mm wide, variable depth channel with Affiner grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd. The channel will be supplied with an enclosed sill section, made to suit as per dimensions on drawing number __________. The channels overall depth, length, outlet position/s and outlet diameter/s are specified on drawing number/s __________.All components used within the scope of the systems are shown on drawing number/s __________. All work should be carried out strictly in accordance with the manufacturers instructions and the installation details set out on drawing number/s __________. | |
100
|
RTE100A
|
The floor channel and grates are to be type RTE100A (100mm wide, variable depth channel with Affiner grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd. The channel will be supplied with an enclosed sill section, made to suit as per dimensions on drawing number __________. The channels overall depth, length, outlet position/s and outlet diameter/s are specified on drawing number/s __________.All components used within the scope of the systems are shown on drawing number/s __________. All work should be carried out strictly in accordance with the manufacturers instructions and the installation details set out on drawing number/s __________. | ||
123
|
RTE123A
|
The floor channel and grates are to be type RTE123A (123mm wide, variable depth channel with Affiner grates) grade 304/316 stainless steel, as supplied by ACO Pty Ltd. The channel will be supplied with an enclosed sill section, made to suit as per dimensions on drawing number __________. The channels overall depth, length, outlet position/s and outlet diameter/s are specified on drawing number/s __________.All components used within the scope of the systems are shown on drawing number/s __________. All work should be carried out strictly in accordance with the manufacturers instructions and the installation details set out on drawing number/s __________. |
ProfiLine
The channel drainage shall be ACO ProfiLine – as supplied and manufactured by ACO Pty Ltd. The ProfiLine channel features perforations to facilitate subsurface drainage and a Stainless 5 Star Heelsafe Anti-Slip / Stainless Slotted / Stainless Mesh / Galvanised Slotted / Galvanised Mesh grate for surface drainage.